Audited Compliance

Certificates & Engineering Standards

Every grounding electrode and lightning arrester is certified by national labs (CPRI) and global bodies to guarantee safety.

Central Power Research Institute (CPRI) Certified

Our Saumya Earthing Electrodes have undergone rigorous testing at the **Central Power Research Institute (CPRI)** of India. The test reports confirm our copper-bonding thickness (minimum 250 microns), mechanical tensile strength, and current-carrying capacity (withstanding up to 40kA short-circuit faults without warping or connection failures).

Official CPRI Test CertificateRef: CPRI/STC/EARTH-2023-A
Quality Audits

Our ISO & Global Quality Audits

ISO 9001

ISO 9001:2015 Quality Management

Our production facility in Raipur operates under a certified ISO 9001:2015 system. This ensures every copper-bonded electrode, equipotential busbar, and APCS controller is manufactured to strict, repeatable tolerance limits.

ISO 14001

ISO 14001:2015 Environmental Management

Conforms to international guidelines for waste reduction and ecological sustainability. Our proprietary NEEC chemical compound is certified non-toxic and presents no threat to the local water tables.

ISO 45001

ISO 45001:2018 Occupational Health

Guarantees a safe working environment at our manufacturing factory and during turnkey field installations under hazardous site conditions.

CE & RoHS

CE Mark and RoHS Standards

Our lightning protection terminals and surge protection devices (SPDs) are officially certified to conform with European CE safety standards and contain no restricted hazardous substances (RoHS).

Engineering Codes

Indian & Global Engineering Codes Adhered To

IS 3043:2018

Indian Standard Code of Practice for Earthing

Our main sizing calculators and BoQ designs follow the detailed recommendations of the IS 3043 code.

IEEE 80-2000

IEEE Guide for Safety in AC Substation Grounding

Mandated for our high-voltage substation designs, computing step and touch voltage hazards in rocky soils.

IEC 62561-7

Requirements for Earthing Enhancing Compounds

Our NEEC crystalline backfill compound conforms to chemical inertness and low resistivity guidelines.

UNE 21.186 / NF C 17-102

Early Streamer Emission Protection Radius

Our Cirprotec NLP 2200 lightning arresters conform strictly to French and Spanish ESE standards.

IEC 61643-11

Low-Voltage Surge Protective Devices Standard

Our distributed Mersen surge protection devices conform to global IEC overvoltage safety and response limits.

IS 694 : 2010

Indian Standard for PVC Insulated Cables

Our grounding loops incorporate Bonton multi-strand copper cables that are officially ISI marked and certified.